Promise Technology FastTrak SX4000 Lite Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Controladores periféricos Promise Technology FastTrak SX4000 Lite. Promise Technology FastTrak SX4000 Lite User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 78
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
FastTrak
S150 SX4 / SX4000 /
SX4000 Lite
User Manual
Version 3.7
Vista de página 0
1 2 3 4 5 6 ... 77 78

Resumo do Conteúdo

Página 1 - FastTrak

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual Version 3.7

Página 2 - Trademarks

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 4 Warning Before installing the adapter into an existing system, backup any important or usef

Página 3

Chapter 2: Installation 5 Memory Module Test The FastTrak S150 SX4, SX4000 and SX4000 Lite RAID Controller cards ship without a Dual Inline Memory

Página 4

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 6 Installing the FastTrak Card The FastTrak RAID Controller card fits into any available: •

Página 5 - Contents

Chapter 2: Installation 7 Installing the Hard Drives Important If you wish to include your current bootable Serial ATA drive using the Windows XP

Página 6

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 8 SX4J1FastTrak 150 Figure 2. FastTrak S150 SX4 card. SX4000FastTRAK111 1J1 Figure 3. Fas

Página 7 - Chapter 1: Introduction

Chapter 2: Installation 9 You will now use the onboard FastBuild BIOS utility to create your first array using the attached drives. For an explanat

Página 8

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 10 FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.[ Define Array Menu ][ Ke

Página 9 - Chapter 2: Installation

Chapter 2: Installation 11 6. Press the arrow keys to move to the next option. Option choices depend on the RAID Level you selected. • Initialize

Página 10

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 12

Página 11 - Memory Module Test

13 Chapter 3: FastBuild™ Utility This chapter contains a Setup Task Quick Reference that is a checklist of tasks needed to initialize your FastTrak

Página 12

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual ii Copyright © 2003, Promise Technology, Inc. All Rights Reserved. Copyright by Promise Technol

Página 13 - Installing the Hard Drives

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 14 Entering the FastBuild utility When the system boots, you will see the Promise FastTrak BIOS

Página 14 - FastTRAK

Chapter 3: FastBuild™ Utility 15 FastTrak BIOS Reference When the FastTrak BIOS loads during bootup, it displays pertinent information about the RA

Página 15

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 16 Status Shows one of three possible array status conditions: Functional The array is fully op

Página 16

Chapter 3: FastBuild™ Utility 17 Main Menu FastBuild Array Utility 2.xx (c) 2002-2005 Promise Technology, Inc.[ Main Menu ]View Drive Assignments .

Página 17

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 18 View Drive Assignments Press 1 on the Main Menu screen, to see the View Drive Assignments sc

Página 18

Chapter 3: FastBuild™ Utility 19 Define Array Press 2 on the Main Menu screen to display, the Define Array Menu (see below). This screen displays

Página 19 - Setup Quick Reference

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 20 Define Array Definition Menu Selecting an Array from the Define Array Menu brings up the Def

Página 20

Chapter 3: FastBuild™ Utility 21 Gigabyte Boundary The Gigabyte Boundary feature is designed for fault tolerant arrays (RAID 1, 0+1 and 5) in which

Página 21 - FastTrak BIOS Reference

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 22 Creating a RAID 0 Array In the Define Array Definition Menu section (see Figure 8), press th

Página 22 - Offline

Chapter 3: FastBuild™ Utility 23 Creating a RAID 1 Array In the Define Array Definition Menu section, press the Spacebar to cycle through array typ

Página 23 - Main Menu

iii Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursua

Página 24 - View Drive Assignments

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 24 Creating a RAID 0+1 Array You must assign four drives to an array before this feature become

Página 25 - Define Array

Chapter 3: FastBuild™ Utility 25 Creating a RAID 5 Array In the Define Array Definition Menu section, press the Spacebar to cycle through array typ

Página 26 - Define Array Definition Menu

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 26 Hot Spare Drives Any extra drive that is not assigned to an array will be recognized as a Sp

Página 27 - Gigabyte Boundary

Chapter 3: FastBuild™ Utility 27 Setting a Disk Array as Bootable You may select which defined array will be used as the bootable array from the D

Página 28 - Creating a RAID 0 Array

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 28 Disk Array Recognition Order During computer startup, the disk arrays on the FastTrak Contro

Página 29 - Creating a RAID 1 Array

Chapter 3: FastBuild™ Utility 29 Delete Array Press 3 on the Main Menu screen to display the Delete Array Menu (below). FastBuild Array Utility 2.x

Página 30 - Creating a RAID 0+1 Array

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 30 Controller Configuration Press 4 on the Main Menu screen to display the Controller Configura

Página 31 - Creating a RAID 5 Array

31 Chapter 4: Installing Software Drivers Following are driver installation procedures for the FastTrak S150 SX4 and SX4000 / SX4000 Lite RAID Con

Página 32 - Partition and Format Array

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 32 Windows Server 2003 Install Driver During New OS Installation 1. Start the installation: B

Página 33

Chapter 4: Installing Software Drivers 33 Install Driver in an Existing System Important If you plan to move the boot drive containing the existin

Página 34 - Saved Disk Array Information

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual iv

Página 35 - Delete Array

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 34 Windows XP Install Driver During New OS Installation 1. Start the installation: Boot from

Página 36 - Controller Configuration

Chapter 4: Installing Software Drivers 35 Install Driver in an Existing System Important If you plan to move the boot drive containing the existin

Página 37

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 36 Windows 2000 Install Driver During New OS Installation 1. Start the installation: Boot fro

Página 38 - Windows Server 2003

Chapter 4: Installing Software Drivers 37 Install Driver in an Existing System Important If you plan to move the boot drive containing the existin

Página 39 - Confirming Installation

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 38 Red Hat Linux 8.0, 9.0 Install Driver During New OS Installation 1. Start the RedHat Linux

Página 40 - Windows XP

Chapter 4: Installing Software Drivers 39 SuSE Linux 8.1, 8.2 Install Driver During New OS Installation: Single Processor Computer 1. Insert the i

Página 41

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 40 Promise RAID Utility for Linux To install the utility, type the following commands: mount /d

Página 42 - Windows 2000

41 Chapter 5: Disk Array Concepts About FastTrak S150 SX4 and SX4000 / SX4000 Lite FastTrak S150 SX4 and SX4000 / SX4000 Lite are high performance

Página 43

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 42 Disk Array Terms Disk Array Description A disk array is formed from a group of two or more d

Página 44 - Red Hat Linux 8.0, 9.0

Chapter 5: Disk Array Concepts 43 RAID Level Performance Fault Tolerance Capacity No. of Drives RAID 0 (Striping) Highest No No. Drives x Smalles

Página 45 - SuSE Linux 8.1, 8.2

v Contents Chapter 1: Introduction... 1 FastTrak S150

Página 46

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 44 Mirroring (RAID 1) Writes duplicate data on to a pair of drives while reads are performed in

Página 47 - Reserved Sector

Chapter 5: Disk Array Concepts 45 Striping / Mirroring (RAID 0+1) A combination of RAID 0 and RAID 1 arrays. It can increase performance by reading

Página 48 - Disk Array Terms

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 46 About Dual Data Redundancy One unique (though rarely occurring) feature of RAID 0+1 is dual

Página 49 - About RAID Levels

Chapter 5: Disk Array Concepts 47 Block and Parity Striping (RAID 5) RAID 5 calculates parity in order to achieve redundancy rather than writing a

Página 50 - Mirroring (RAID 1)

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 48 JBOD - Single Drive An alternative to RAID, Just a Bunch of Disks (JBOD) capacity is equal t

Página 51 - Data Stripe

49 Chapter 6: Troubleshooting & Tips This section is used to assist with troubleshooting conflicts and FastTrak S150 SX4 or SX4000 / SX4000 Lit

Página 52 - About Dual Data Redundancy

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 50 Miscellaneous problems such as: • FastTrak S150 SX4 BIOS does not appear during boot • Fas

Página 53 - Distributed Parity

Chapter 6: Troubleshooting & Tips 51 Drive-Related Errors Critical Array Status Error Reported during Boot If a critical status error message a

Página 54 - JBOD - Single Drive

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 52 Unable to Partition or Format Array There are two possible causes: • The FastTrak Controlle

Página 55 - Motherboard Issues

Chapter 6: Troubleshooting & Tips 53 To remove the Reserve Sector, follow these steps: 1. During boot up, press Ctrl-F to enter the FastBuild

Página 56 - System CMOS Issues

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual vi Chapter 5: Disk Array Concepts...

Página 57 - Drive-Related Errors

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 54 Operating System-Related Issues Different drive lettering under Windows NT This may happen w

Página 58

Chapter 6: Troubleshooting & Tips 55 Performance Tips Here are some tips that may optimize performance in a RAID 0 striped array. If you are us

Página 59

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 56

Página 60

57 Appendix A: Frequently Asked Questions This section lists frequently asked questions involving pre-installation, drive issues, installation, and

Página 61 - Performance Tips

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 58 Q: How do the FastTrak S150 SX4 and SX4000 / SX4000 Lite RAID Controllers provide storage a

Página 62

Appendix A: FAQs 59 RAID 5 (Block and Parity Striping) For capacity – The FastTrak RAID 5 array is the smallest drive size multiplied by the numb

Página 63 - Pre-Installation

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 60 Drive Issues Q: Can I add a drive to a FastTrak S150 SX4 or SX4000 / SX4000 Lite array via

Página 64

Appendix A: FAQs 61 Q: Do I have to install disk management software on my array in order to access the full storage capacity of drives? A: No! D

Página 65 - Appendix A: FAQs

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 62 Installation Issues (Capacity, Booting) Q: Why are some drives recognized by the FastTrak

Página 66 - Drive Issues

63 Appendix B: Technical Support Promise Technical Support provides several support options for Promise users to access information and updates. We

Página 67

1 Chapter 1: Introduction FastTrak S150 SX4 and SX4000 / SX4000 Lite FastTrak S150 SX4 and SX4000 / SX4000 Lite are RAID controllers and a software

Página 68 - Post-Installation

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 64 Pacific Rim Sales Office E-mail Support [email protected] Fax Technical Support +88

Página 69 - Technical Support Services

Appendix B: Technical Support 65 Limited Warranty Promise Technology, Inc. (“Promise”) warrants that for Three (3) years from the time of the deliv

Página 70

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 66 No other document, statement or representation may be relied on to vary the terms of this li

Página 71 - Limited Warranty

Appendix B: Technical Support 67 Returning Product for Repair If you suspect a product is not working properly, or if you have any questions about

Página 72 - Your Responsibilities

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 68

Página 73 - Returning Product for Repair

69 Appendix C: Features and Specifications Disk Array Features Supported RAID Levels: • RAID 0 – striping for performance • RAID 1 – disk mirrori

Página 74

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 70 Hardware Features 32-bit / 66MHz6 PCI interface compliant to PCI Rev 2.2 PCI bus mastering D

Página 75 - Disk Array Features

Appendix C: Features and Specifications 71 Physical & Environmental Size 9.84 x 3.82 inches (25.0 x 9.7 cm) Operating temperature: 32° to 122°F

Página 76 - Advanced Utilities

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 72

Página 77 - Physical & Environmental

FastTrak S150 SX4 / SX4000 / SX4000 Lite User Manual 2 Promise Array Management Utility (PAM) The Promise Array Management (PAM) utility offers loca

Página 78

3 Chapter 2: Installation S150 SX4 When you receive the FastTrak S150 Series card, the package should contain the items listed below: • FastTrak S

Comentários a estes Manuais

Sem comentários