Promise Technology Network Device EX8654 Manual do Utilizador Página 199

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 238
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 198
Chapter 6: Technology Background
187
Automatic Transition
At this juncture, you would replace the failed drive in channel 2 with a new drive
of the same or greater capacity.
When the SuperTrak controller detects the new drive in channel 2, it will:
Transition the data from the drive in channel 4 to the drive in channel 2.
Return the drive in channel 4 to spare status.
When the Transition is finished:
The physical drives in channels 1 and 2 belong to the disk array.
The physical drive in channel 3 is still unconfigured.
The physical drive in channel 4 is a revertible spare drive.
The original configuration is restored.
Manual Transition
Manual transition requires an unassigned physical drive.
The example below is the same two-drive RAID 1 disk array as before.
The physical drives in channels 1 and 2 belong to the disk array.
The physical drive in channel 3 is unconfigured.
The physical drive in channel 4 is a revertible spare drive.
Vista de página 198
1 2 ... 194 195 196 197 198 199 200 201 202 203 204 ... 237 238

Comentários a estes Manuais

Sem comentários