VessRAID 1730s, 1740s,1830s, 1840sProduct ManualVersion 1.1

Página 2 - Recommendations

VessRAID 1000s Series Product ManualxChapter 5: Management with the CLU, cont.Managing Disk Arrays, cont.Running PDM . . . . . . . . . . . . . . . .

Página 3

VessRAID 1000s Series Product Manual84Starting Up After ShutdownTo start the RAID subsystem:1. Manually turn on the power supply switches on the back

Página 4

Chapter 4: Management with WebPAM PROe85Restarting the SubsystemYou can only do part of this function in WebPAM PROe. Additional action is required, a

Página 5

VessRAID 1000s Series Product Manual86Managing the ControllerThe RAID controller is the heart of the VessRAID subsystem. Controller management include

Página 6

Chapter 4: Management with WebPAM PROe87• Write Back Cache Flush Interval• Enclosure Polling IntervalSee “Making Controller Settings” on page 87.Upgra

Página 7

VessRAID 1000s Series Product Manual885. Make the following settings as needed:• Enter a name into the Alias field. Maximum of 48 characters. Use lett

Página 8

Chapter 4: Management with WebPAM PROe89To clear an Orphan Watermark:1. Click the Subsystem icon in Tree View. 2. Click the Controllers icon. 3. C

Página 9

VessRAID 1000s Series Product Manual90Managing EnclosuresOn VessRAID, enclosures include the main VessRAID subsystem or Head Unit as well as VessJBOD

Página 10

Chapter 4: Management with WebPAM PROe91Figure 6. Disk Status LEDFigure 7. VessRAID enclosure LEDsViewing Enclosure TopologyTo view Enclosure Topology

Página 11 - Contents

VessRAID 1000s Series Product Manual922. Click the Enclosures icon. 3. Click the Enclosure icon.Enclosure information appears the Information tab

Página 12

Chapter 4: Management with WebPAM PROe933. Click the Enclosure icon. 4. Click the FRU VPD tab in Management View. Use this information when communic

Página 13

ContentsxiChapter 5: Management with the CLU, cont.Working with LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172Viewing a Li

Página 14

VessRAID 1000s Series Product Manual94Reconditioning a BatteryTo recondition the battery:1. Click the Subsystem icon in Tree View. 2. Click the Encl

Página 15

Chapter 4: Management with WebPAM PROe954. In Management View, from the Buzzer tab dropdown menu, choose Settings. 5. Check the Buzzer Enable box to e

Página 16

VessRAID 1000s Series Product Manual96Managing Physical DrivesManaging Physical Drives deals with the physical disk drives installed in the VessRAID s

Página 17 - About This Manual

Chapter 4: Management with WebPAM PROe97Making Global Physical Drive SettingsGlobal settings apply to all of the physical disk drives installed in the

Página 18 - VessRAID Overview

VessRAID 1000s Series Product Manual98• Operational Status – OK is normal. Can also show Rebuilding, Forced Online, Forced Offline, Transition Running

Página 19 - Features and Benefits

Chapter 4: Management with WebPAM PROe996. Click the Settings tab in Management View. 7. Type an alias into the Physical Drive Alias field. Maximum of

Página 20 - Operational Features

VessRAID 1000s Series Product Manual100Forcing a Physical Drive Offline or OnlineThe Physical Drive–Force Offline/Online tab enables you to force an:•

Página 21 - Management

Chapter 4: Management with WebPAM PROe1016. Click the physical drive you want to locate on the WebPAM PROe screen.The disk status LED for the physical

Página 22 - Specifications

VessRAID 1000s Series Product Manual102Managing UPS UnitsUninterruptible Power Supply (UPS) Management includes the following functions:• Viewing a Li

Página 23

Chapter 4: Management with WebPAM PROe103Making UPS SettingsThese settings control how the VessRAID subsystem detects the UPS unit and responds to dat

Página 24 - KCC Statement

VessRAID 1000s Series Product ManualxiiChapter 6: Management with the LCD Panel . . . . . . . . . . . . . . . . . .195Using the LCD Panel . . . . . .

Página 25 - Unpacking the VessRAID

VessRAID 1000s Series Product Manual104Viewing UPS InformationTo view information about a specific UPS unit:1. Click the Subsystem icon in Tree View

Página 26

Chapter 4: Management with WebPAM PROe105Managing Disk ArraysDisk Array Management includes the following functions:• Viewing Disk Arrays (page 105)•

Página 27

VessRAID 1000s Series Product Manual106• Advanced – You directly specify all parameters for a new disk array. Makes one logical drive automatically. Y

Página 28

Chapter 4: Management with WebPAM PROe107Creating a Disk Array – ExpressThe Disk Array Express Creation option enables you to choose the parameters fo

Página 29 - Mounting VessRAID in a Rack

VessRAID 1000s Series Product Manual108The following parameters display: • Disk Arrays – The number of physical drives in the disk array, their slot n

Página 30

Chapter 4: Management with WebPAM PROe109migration of data from the suspect drive (the disk drive with the bad sectors) to a spare disk drive. 3. From

Página 31 - Installing Disk Drives

VessRAID 1000s Series Product Manual11011. When you have finished specifying logical drives, click the Next button. Step 3 – SummaryThe Summary lists

Página 32 - Installing Your Disk Drives

Chapter 4: Management with WebPAM PROe111Disk Array Operational Status• OK – The normal state of a disk array. For RAID Levels other than RAID 0 (Stri

Página 33

VessRAID 1000s Series Product Manual112Creating a Logical DriveWhen you create a disk array, you automatically create one logical drive also. If the i

Página 34 - Configuring a Management Path

Chapter 4: Management with WebPAM PROe11313. Click the Update button to enter the logical drive parameters. 14. Review the results. If there is remain

Página 35

ContentsxiiiChapter 7: Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219Updating the Firmware in WebPAM PROe . . .

Página 36

VessRAID 1000s Series Product Manual114For a list of Migration options and other important information, see “RAID Level Migration” on page 252.To Migr

Página 37 - Connecting the Power

Chapter 4: Management with WebPAM PROe115Rebuilding AutomaticallyNormally, a disk array would rebuild itself using a hot disk drive, after going Criti

Página 38

VessRAID 1000s Series Product Manual116To start Media Patrol: 1. Click the Subsystem icon in Tree View. 2. Click the Disk Arrays icon. 3. Click th

Página 39

Chapter 4: Management with WebPAM PROe117To run Transition:1. Click the Subsystem icon in Tree View. 2. From the dropdown menu on the Background Act

Página 40

VessRAID 1000s Series Product Manual118Managing Logical DrivesLogical drives are made from disk arrays. In the Tree, you can see a graphic representat

Página 41 - Chapter 3: VessRAID Setup

Chapter 4: Management with WebPAM PROe119may remain intact. You must determine the cause of the problem and correct it. “Critical & Offline Disk A

Página 42 - Default IP Address

VessRAID 1000s Series Product Manual120Viewing Logical Drive StatisticsTo view information for a single logical drive:1. Click the Subsystem icon in

Página 43 - Setting up with the CLI

Chapter 4: Management with WebPAM PROe121because there may be residual data the logical drives left behind from earlier configurations. For this reaso

Página 44 - Setting up with the CLU

VessRAID 1000s Series Product Manual1223. Click the icon of the logical drive you want to Initialize. You can also start Redundancy check from the S

Página 45 - Making Automatic IP Settings

Chapter 4: Management with WebPAM PROe123Table Definitions• Read Check Table – Contains a list of read errors for this logical drive. • Write Check Ta

Página 46 - Setting up with the LCD

VessRAID 1000s Series Product ManualxivChapter 8: Technology Background, cont.Choosing Stripe Size . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 47

VessRAID 1000s Series Product Manual124Managing Spare DrivesWhen a physical drive in a disk array fails and a spare drive of adequate capacity is avai

Página 48 - Logging into WebPAM PROe

Chapter 4: Management with WebPAM PROe1253. Click the Spare Drive icon. In Management View, the Enclosure Front View diagram appears with the locati

Página 49

VessRAID 1000s Series Product Manual12610. If you selected a Dedicated spare drive, in the Dedicated to Disk Arrays field, highlight disk arrays to wh

Página 50 - Choosing a Language

Chapter 4: Management with WebPAM PROe1277. If you selected a Dedicated spare drive, in the Dedicated to Disk Arrays field, highlight the disk arrays

Página 51 - Automatic

VessRAID 1000s Series Product Manual128Working with the Logical Drive SummaryThe Logical Drive Summary displays a list of all logical drives in the Ve

Página 52

129Chapter 5: Management with the CLUThis chapter covers the following topics:• Initial Connection (page 130)• Running Quick Setup (page 134)• Managin

Página 53 - Advanced

VessRAID 1000s Series Product Manual130Initial ConnectionMaking an initial connection includes the following functions:• Making a Serial Connection (b

Página 54 - Logging out of WebPAM PROe

Chapter 5: Management with the CLU131Making a Telnet ConnectionA Telnet connection requires a network connection between the Host PC and VessRAID cont

Página 55

VessRAID 1000s Series Product Manual132Figure 3. CLU main menuQuick Setup – A sequence of four steps to setup System Date & Time, Management Port,

Página 56

Chapter 5: Management with the CLU133Background Activity – Settings for Media Patrol, Auto Rebuild, Rebuild, Migration, PDM, Transition, Synchronizati

Página 57

ContentsxvChapter 9: Troubleshooting, cont.LCD Panel Reports a Problem . . . . . . . . . . . . . . . . . . . . . . . . . . .275Viewing a Report from

Página 58

VessRAID 1000s Series Product Manual134Running Quick SetupQuick Setup is discussed under “Setting up the Serial Connection” on page 25.

Página 59 - Selecting a Language

Chapter 5: Management with the CLU135Managing the SubsystemSubsystem Management includes the following functions:• Setting an Alias for the Subsystem

Página 60

VessRAID 1000s Series Product Manual1364. Highlight Lock and press Enter.Resetting the LockTo reset the lock with a new time:1. From the Main Menu, hi

Página 61 - Using the Header

Chapter 5: Management with the CLU137Managing the ControllerController Management includes the following functions:• Viewing Controller Information (p

Página 62 - Using Tree View

VessRAID 1000s Series Product Manual1383. Highlight the controller you want and press Enter.4. Highlight Controller Settings and press Enter.5. Make t

Página 63 - Viewing the Event Frame

Chapter 5: Management with the CLU139Figure 4. Controller Status LEDController Status

Página 64

VessRAID 1000s Series Product Manual140Managing the EnclosureEnclosure Management includes the following functions:• Viewing Enclosure Information (pa

Página 65 - Hiding the Other Subsystems

Chapter 5: Management with the CLU141Locating a Power SupplyTo locate a power supply:1. From the Main Menu, highlight Subsystem Management and press E

Página 66 - Working with Subsystems

VessRAID 1000s Series Product Manual142Setting Temperature ThresholdsTo change temperature thresholds:1. From the Main Menu, highlight Subsystem Manag

Página 67 - Viewing the Runtime Event Log

Chapter 5: Management with the CLU143controller before reconditioning is finished, the battery is charged to 100%, then reconditioning starts again.Re

Página 68 - Viewing NVRAM Events

VessRAID 1000s Series Product Manualxvi

Página 69 - Saving NVRAM Events

VessRAID 1000s Series Product Manual144Figure 6. VessRAID enclosure LEDsViewing Enclosure TopologyEnclosure topology refers to the manner in which the

Página 70

Chapter 5: Management with the CLU145Managing Physical DrivesPhysical Drive Management includes the following functions:• Making Global Physical Drive

Página 71 - Running Media Patrol

VessRAID 1000s Series Product Manual146Setting an AliasAn alias is optional. To set an Alias for a physical drive:1. From the Main Menu, highlight Phy

Página 72 - Scheduling an Activity

Chapter 5: Management with the CLU147After you clear a PFA error, watch for another PFA error to appear. If it does, replace the physical drive. Forci

Página 73 - Deleting a Scheduled Activity

VessRAID 1000s Series Product Manual148Managing Disk ArraysDisk Array Management includes the following functions:• Creating a Disk Array (page 148)•

Página 74 - Renewing the Lock

Chapter 5: Management with the CLU149Creating a Disk Array – AutomaticTo create a disk array using the Automatic feature:1. From the Main Menu, highli

Página 75

VessRAID 1000s Series Product Manual150Creating a Disk Array – ExpressTo create a disk array using the Express feature:1. From the Main Menu, highligh

Página 76

Chapter 5: Management with the CLU151Creating a Disk Array – AdvancedFor more information on the choices below, see “Chapter 8: Technology Background”

Página 77 - Making Your Own User Settings

VessRAID 1000s Series Product Manual15217. Highlight Save Logical Drive and press Enter.18. Review logical drive(s) you are about to create for your n

Página 78 - Changing Your Own Password

Chapter 5: Management with the CLU153• Synchronizing – When you first create a disk array, the disk array synchronizes. During that time, your data is

Página 79 - Creating a User

1Chapter 1: Introduction to VessRAIDThis chapter covers the following topics:• About This Manual (below)• VessRAID Overview (page 2)• Architectural De

Página 80 - Logging out Other Users

VessRAID 1000s Series Product Manual154Enabling Media Patrol on a Disk ArrayMedia Patrol checks the magnetic media on physical drives.To enable or dis

Página 81

Chapter 5: Management with the CLU155The available drives are either HDD or SSD, depending on the type of drives in the array.6. Highlight Start and p

Página 82

VessRAID 1000s Series Product Manual156The screen jumps to Disk Arrays Summary.Running PDMBe sure PDM must be enabled. See “Enabling PDM on a Disk Arr

Página 83

Chapter 5: Management with the CLU157To locate a disk array:1. From the Main Menu, highlight Disk Array Management and press Enter.2. Highlight the di

Página 84 - Managing Storage Services

VessRAID 1000s Series Product Manual158• Write Policy – Press spacebar to choose: Write Back or Write Through• Read Policy – Press spacebar to choose:

Página 85 - Adding a LUN Map

Chapter 5: Management with the CLU159Managing Spare DrivesSpare Drive Management includes the following functions:• Viewing a list of Spare Drives (pa

Página 86 - Editing a LUN Map

VessRAID 1000s Series Product Manual160Dedicated means this spare drive can only be used with the specified disk arrays. Global means this spare drive

Página 87 - Managing Software Services

Chapter 5: Management with the CLU161Deleting a Spare Drive To delete a spare drive:1. From the Main Menu, highlight Spare Drive Management and press

Página 88

VessRAID 1000s Series Product Manual162Managing Logical DrivesThe Logical Drive Management function deals with settings and functions of existing logi

Página 89

Chapter 5: Management with the CLU1633. To set write cache policy for this logical drive, highlight WritePolicy and press the spacebar to toggle betwe

Página 90

VessRAID 1000s Series Product Manual2VessRAID OverviewVessRAID provides data storage solutions for applications where high performance and data protec

Página 91 - Deleting Trap Sinks

VessRAID 1000s Series Product Manual164Running Redundancy CheckRedundancy Check is a maintenance procedure for logical drives in fault-tolerant disk a

Página 92

Chapter 5: Management with the CLU165Managing the Network ConnectionThe network connection deals with the VessRAID’s Management Port.• Making Manageme

Página 93 - Stopping Netsend service

VessRAID 1000s Series Product Manual166Managing SAS ConnectionsSAS connections deal with the VessRAID’s two host data ports.• Viewing SAS Port Informa

Página 94 - Importing a User Database

Chapter 5: Management with the CLU167Viewing SAS Port StatisticsThere are two SAS data ports on the controller. To view information about the SAS port

Página 95

VessRAID 1000s Series Product Manual168Managing Background ActivityBackground activity refers to any of several functions that take place in the backg

Página 96

Chapter 5: Management with the CLU169• PDM – Looks for bad blocks on the physical drives of disk arrays• Transition – Returns a revertible spare drive

Página 97

VessRAID 1000s Series Product Manual170Working with the Event ViewerThe Event Viewer displays log of subsystem events. Events are classified as:• Runt

Página 98

Chapter 5: Management with the CLU171To display NVRAM events:1. From the Main Menu, highlight Event Viewer and press Enter.2. Highlight NVRAM Events a

Página 99 - Monitoring the Shutdown

VessRAID 1000s Series Product Manual172Working with LUN MappingLUN Mapping includes the following functions:• Viewing a List of Initiators (page 172)•

Página 100 - Starting Up After Shutdown

Chapter 5: Management with the CLU173A SAS initiator name is the SAS address of the HBA card in the Host PC.Obtain the initiator name from the initiat

Página 101 - Restarting the Subsystem

Chapter 1: Introduction to VessRAID3Architectural DescriptionThe VessRAID 1700s and 1800s Series are Serial Attached SCSI (SAS) subsystems suitable fo

Página 102 - Managing the Controller

VessRAID 1000s Series Product Manual174Managing UPS UnitsUninterruptible Power Supply (UPS) Management includes the following functions:• Viewing a Li

Página 103 - Making Controller Settings

Chapter 5: Management with the CLU175Making UPS SettingsThese settings control how the VessRAID subsystem detects the UPS unit and responds to data re

Página 104 - Clearing an Orphan Watermark

VessRAID 1000s Series Product Manual176Figure 1.Viewing UPS InformationTo view information about a specific UPS unit:1. From the Main Menu, highlight

Página 105

Chapter 5: Management with the CLU177Managing UsersUser Management includes the following functions:• Viewing User Information (page 177)• Creating a

Página 106 - Managing Enclosures

VessRAID 1000s Series Product Manual178List of User Privileges• View – Allows the user to see all status and settings but not to make any changes • Ma

Página 107 - Viewing Enclosure Topology

Chapter 5: Management with the CLU1796. Press Ctrl-A to save the settings.Changing a User’s Privilege and StatusNo user can change their own privilege

Página 108 - Viewing FRU VPD Information

VessRAID 1000s Series Product Manual180Working with Software ManagementSoftware Management includes the following functions:• Making Email Settings (p

Página 109 - Checking the Battery

Chapter 5: Management with the CLU181Making SLP SettingsBy default, SLP service is set to Automatic and its normal status is Started.To make SLP servi

Página 110 - Making Buzzer Settings

VessRAID 1000s Series Product Manual182Making Telnet SettingsBy default, Telnet service is set to Automatic and its normal status is Started. To make

Página 111 - Testing the Buzzer

Chapter 5: Management with the CLU1836. Press Ctrl-A to save your settings.To start, stop or restart the SNMP service, highlight Start, Stop, or Resta

Página 112 - Managing Physical Drives

VessRAID 1000s Series Product ManualiiCopyright© 2009 Promise Technology, Inc. All Rights Reserved.Copyright by Promise Technology, Inc. (Promise Tech

Página 113

VessRAID 1000s Series Product Manual4• Three years complete system limited warranty includes 24 x 7 email and phone support with highly experienced te

Página 114 - Clearing Statistics

VessRAID 1000s Series Product Manual184Making Netsend SettingsBy default, Netsend service is set to Manual and its normal status is Stopped.To make Ne

Página 115

Chapter 5: Management with the CLU1852. Highlight Software Management and press Enter.1. Highlight the recipient whose settings you want to change and

Página 116 - Locating a Physical Drive

VessRAID 1000s Series Product Manual186Flashing through TFTPSee “Chapter 7: Maintenance” on page 219 for instructions.Viewing Flash Image InformationF

Página 117 - Disk Status

Chapter 5: Management with the CLU187Restoring Factory DefaultsThis function restores the factory default settings to the firmware and software items

Página 118 - Managing UPS Units

VessRAID 1000s Series Product Manual188Shutting Down the SubsystemThere are two methods for shutting down the subsystem, depending on your connection.

Página 119 - Making UPS Settings

Chapter 5: Management with the CLU189•Shutting down the VessRAID – Serial ConnectionThis function enables you to shutdown the VessRAID subsystem on a

Página 120 - Viewing UPS Information

VessRAID 1000s Series Product Manual190Starting Up After ShutdownThere are two methods for shutting down the subsystem. Choose one:• Starting up the V

Página 121 - Managing Disk Arrays

Chapter 5: Management with the CLU191Restarting the SubsystemThere are two methods for shutting down the subsystem, depending on your connection. Choo

Página 122

VessRAID 1000s Series Product Manual1924. Highlight Submit and press Enter.A warning message appears.5. Press Y to continue.The screen will display sh

Página 123

Chapter 5: Management with the CLU193Making Buzzer SettingsThis function enables the buzzer on the controller. When you first power-up the VessRAID, i

Página 124 - Step 1 – Disk Array Creation

Chapter 1: Introduction to VessRAID5• Maximum LUNs per array: 32 logical drives (LUNs). Supports LUN carving by allowing an array to be divided into m

Página 125

VessRAID 1000s Series Product Manual194

Página 126 - Deleting a Disk Array

195Chapter 6: Management with the LCD PanelThis chapter covers the following topics:• Using the LCD Panel (below)• Perusing the Interface (page 196)•

Página 127 - Making Disk Array Settings

VessRAID 1000s Series Product Manual196Perusing the Interface• Making Mode Settings (page 196)• Simple Mode (page 196)• Advanced Mode (page 197)• Limi

Página 128 - Creating a Logical Drive

Perusing the Interface197Advanced ModeAdvanced Mode enables you to perform the Simple Mode functions, plus:• View Enclosure – View overall enclosure s

Página 129 - Migrating a Disk Array

VessRAID 1000s Series Product Manual198Managing the Network ConnectionThe network connection deals with the VessRAID’s Management Port.• Making Manage

Página 130 - Rebuilding a Disk Array

Managing the Network Connection199Automatic IP SettingsTo make Management Port settings automatically:1. Press the or button until the display say

Página 131 - Rebuilding Manually

VessRAID 1000s Series Product Manual200Managing SAS ConnectionsSAS connections deal with the VessRAID’s two host data ports.• Viewing SAS Port Informa

Página 132 - Transitioning a Disk Array

Managing SAS Connections201• Press button and the button to choose SAS Port 2.4. Press the or button to scroll to Signal Strength.5. Press the

Página 133

VessRAID 1000s Series Product Manual202Managing the ControllerThe RAID controller is the heart of the VessRAID subsystem. To view Controller statistic

Página 134 - Managing Logical Drives

Managing Enclosures203Managing EnclosuresThe LCD panel provides information on the main VessRAID subsystem or Head Unit only. For a JBOD as well as ot

Página 135 - Logical Drive Synchronization

VessRAID 1000s Series Product Manual6SpecificationsPower Supply1840s: 450W, Dual hot-swappable and redundant, 100-240 VAC auto-ranging, 50-60 Hz, with

Página 136 - Initializing a Logical Drive

VessRAID 1000s Series Product Manual204Managing Physical DrivesThese functions require the LCD panel to be in Advanced mode. See page 196. Managing ph

Página 137 - Running Redundancy Check

Managing Physical Drives2056. Press the button. The disk status LED for the physical drive blinks for one minute. See Figure 2.Figure 2. Disk Status

Página 138

VessRAID 1000s Series Product Manual206Managing Disk ArraysDisk Array Management in the LCD includes the following functions:• Creating a Disk Array –

Página 139 - Table Definitions

Managing Disk Arrays207VerifyingTo verify the results of the automatic disk array creation:1. From the default screen, press the or button until t

Página 140 - Managing Spare Drives

VessRAID 1000s Series Product Manual2082. Press the button again and the display says 000.3. Press the button again and the display says RAID Leve

Página 141 - Creating a Spare Drive

Managing Disk Arrays2092. Press the button again to display the available physical drives by number.3. Press the button to move through the list.

Página 142 - Making Spare Drive Settings

VessRAID 1000s Series Product Manual2104. Press the button choose a disk array.5. Press the or button to scroll through the list of items:•ID Nu

Página 143 - Running Spare Check

Managing Disk Arrays2116. Press the button. The disk status LEDs for the physical drives in the disk array blink for one minute. See Figure 3.Figure

Página 144

VessRAID 1000s Series Product Manual212The display shows the default read policy.The choices are ReadCache, ReadAhead and None.14. Press the or bu

Página 145

Managing Disk Arrays213Viewing Logical Drive InformationThis function requires the LCD to be in Advanced mode. See page 196.To view logical drive info

Página 146 - Initial Connection

Chapter 1: Introduction to VessRAID7Dimensions (H x W x D)1840s: 13 x 45 x 46 cm (5.1 x 17.7 x 18.1 in)1830s: 8.8 x 45 x 46 cm (3.5 x 17.7 x 18.1 in)1

Página 147 - Logging In

VessRAID 1000s Series Product Manual214Locating a a Logical DriveThis function requires the LCD to be in Advanced mode. See page 196. This feature hel

Página 148

Managing Spare Drives215Managing Spare DrivesSpare Drive Management on the LCD includes:• Viewing Spare Drive Information (page 215)• Creating a Spare

Página 149 - Logging Out of the CLI

VessRAID 1000s Series Product Manual2162. Press the button and the display says Auto Configure.3. Press the or button until the display says Adv

Página 150 - Running Quick Setup

Managing Spare Drives2174. Press the button choose a spare drive.5. Press the or button until the display says Locate Spare Drive.6. Press the

Página 151 - Managing the Subsystem

VessRAID 1000s Series Product Manual218

Página 152 - Releasing the Lock

219Chapter 7: MaintenanceThis chapter covers the following topics:• Updating the Firmware in WebPAM PROe (below)• Updating the Firmware in the CLU (pa

Página 153

VessRAID 1000s Series Product Manual2205. Do one of the following actions: • Click the Download from TFTP Server option, then click the Next button. •

Página 154 - Locating the Controller

Chapter 7: Maintenance2216. Enter the filename of the Firmware Update file in the field provided.Or, click the Browse... button and choose the Firmwar

Página 155 - Controller Status

VessRAID 1000s Series Product Manual222When the controller shuts down, your WebPAM PROe connection will be lost. 9. Wait for two to three minutes. 10.

Página 156 - Managing the Enclosure

Chapter 7: Maintenance223Restarting Subsystem over a Telnet ConnectionTo restart the VessRAID subsystem on a Telnet connection:1. From the Main Menu,

Página 157 - Viewing Voltage Sensor Status

VessRAID 1000s Series Product Manual8CE StatementWarning: This is a class B product. In a domestic environment this product may cause radio interferen

Página 158 - Checking the Batteries

VessRAID 1000s Series Product Manual224Replacing a Power SupplyVessRAID 1700s SeriesThe power supply on the VessRAID 1700s Series is not replaceable o

Página 159 - Locating an Enclosure

Chapter 7: Maintenance225Replacing a RAID ControllerThe RAID Controller monitors and manages the logical drives. When the controller is replaced, all

Página 160

VessRAID 1000s Series Product Manual226See page 228 and page 230 for more information.2. Carefully slide the new RAID Controller into the enclosure.3.

Página 161

Chapter 7: Maintenance227Figure 3. RAID Controller cover and attaching screw4. Remove the four attaching screws. See Figure 4.5. Detach the fan’s powe

Página 162 - Viewing Advanced Information

VessRAID 1000s Series Product Manual2288. Reinstall the RAID Controller.See “Replacing a RAID Controller” on page 225.This completes the fan replaceme

Página 163

Chapter 7: Maintenance2294. Lay the RAID Controller on a non-static surface and remove the cover attaching screws, one on each side, then remove the c

Página 164

VessRAID 1000s Series Product Manual230Figure 7. Battery connector pins8. Put the battery assembly into place and install the attaching screw.9. Repla

Página 165

Chapter 7: Maintenance231Figure 8. Removing the RAID Controller2. Lay the RAID Controller on a non-static surface and remove the cover attaching screw

Página 166

VessRAID 1000s Series Product Manual232

Página 167

233Chapter 8: Technology BackgroundThis chapter covers the following topics:• Introduction to RAID (below)• Choosing a RAID Level (page 244)• Choosing

Página 168

9Chapter 2: VessRAID InstallationThis chapter covers the following topics:• Unpacking the VessRAID (below)• Installing the LCD Panel (Optional) (page

Página 169 - Accepting an Incomplete Array

VessRAID 1000s Series Product Manual234RAID 0 – StripeWhen a logical drive is striped, the read and write blocks of data are interleaved between the s

Página 170 - Enabling PDM on a Disk Array

Chapter 8: Technology Background235RAID 1 – MirrorWhen a logical drive is mirrored, identical data is written to a pair of physical drives, while read

Página 171

VessRAID 1000s Series Product Manual236RAID 1E – Enhanced MirrorRAID 1E offers the security of mirrored data provided by RAID 1 plus the added capacit

Página 172 - Locating a Disk Array

Chapter 8: Technology Background237RAID 5 – Block and Parity StripeRAID 5 organizes block data and parity data across the physical drives. Generally,

Página 173

VessRAID 1000s Series Product Manual238RAID 6 – Block and Double Parity StripeRAID level 6 stores dual parity data is rotated across the physical driv

Página 174

Chapter 8: Technology Background239RAID 10 – Mirror / StripeMirror + Stripe combines both of the RAID 1 and RAID 0 logical drive types. RAID 10 can in

Página 175

VessRAID 1000s Series Product Manual240RAID 50 – Striping of Distributed ParityRAID 50 combines both RAID 5 and RAID 0 features. Data is striped acros

Página 176

Chapter 8: Technology Background241RAID 50 AxlesWhen you create a RAID 50, you must specify the number of axles. An axle refers to a single RAID 5 log

Página 177 - Deleting a Spare Drive

VessRAID 1000s Series Product Manual242RAID 60 – Striping of Double ParityRAID 60 combines both RAID 6 and RAID 0 features. Data is striped across dis

Página 178

Chapter 8: Technology Background243RAID 60 AxlesWhen you create a RAID 60, you must specify the number of axles. An axle refers to a single RAID 6 log

Página 179 - Setting Read Cache Policy

VessRAID 1000s Series Product Manual10 Figure 1. VessRAID 1730s and 1830s front viewA defective drive may be replaced without interruption of data ava

Página 180 - Locating a Logical Drive

VessRAID 1000s Series Product Manual244Choosing a RAID LevelThere are several issues to consider when choosing the RAID Level for your VessRAID disk a

Página 181 - Making Manual Settings

Chapter 8: Technology Background245RAID 1ERecommended Applications for RAID 1E• Imaging applications • Database servers • General file serverRAID 5Rec

Página 182 - Managing SAS Connections

VessRAID 1000s Series Product Manual246RAID 10Recommended Applications for RAID 10• Imaging applications • Database servers • General file serverRAID

Página 183 - Adding a SAS Initiator

Chapter 8: Technology Background247Choosing Stripe SizeStripe Size, also called “Stripe Block Size”, refers to the size of the data blocks written to,

Página 184 - Managing Background Activity

VessRAID 1000s Series Product Manual248• Linux operating systems with the 2.6 kernel support 64-bit LBA. For these OSes, always choose the default 512

Página 185

Chapter 8: Technology Background249Read Cache Policy• Read Cache – The read cache is enabled. • Read Ahead – The read cache and the read-ahead feature

Página 186 - Working with the Event Viewer

VessRAID 1000s Series Product Manual250To enable the Adaptive Writeback Cache option, see “Making Controller Settings” on page 87 (WebPAM PROe) or pag

Página 187 - Clearing NVRAM Events

Chapter 8: Technology Background251InitializationInitialization is done to logical drives after they are created from a disk array. Initialization set

Página 188 - Working with LUN Mapping

VessRAID 1000s Series Product Manual252Partition and Format the Logical DriveLike any other type of fixed disk media in your system, a RAID logical dr

Página 189 - Deleting an Initiator

Chapter 8: Technology Background253RAID 0A RAID 0 source logical drive can migrate to the following target logical drives:Target RequirementsRAID 0 Ad

Página 190

Chapter 2: VessRAID Installation11Figure 3. VessRAID 1730s rear viewFor a description of the RAID Controller LEDs, see page 22.Installing the LCD Pane

Página 191

VessRAID 1000s Series Product Manual254RAID 1A RAID 1 Source logical drive can migrate to the following Target logical drives:RAID 1EA RAID 1E Source

Página 192

Chapter 8: Technology Background255RAID 5A RAID 5 Source logical drive can migrate to the following Target logical drives:RAID 6A RAID 6 Source logica

Página 193 - Managing Users

VessRAID 1000s Series Product Manual256RAID 10A RAID 10 Source logical drive can migrate to the following Target logical drives:Target RequirementsRAI

Página 194 - Changing a User’s Password

Chapter 8: Technology Background257RAID 50A RAID 50 Source logical drive can migrate to the following Target logical drives:RAID 60A RAID 60 Source lo

Página 195 - Deleting a User

VessRAID 1000s Series Product Manual258Ranges of Disk Array ExpansionThe Windows 2000 and Windows XP (32-bit) operating systems support a 10-byte LBA

Página 196 - Making Email Settings

Chapter 8: Technology Background259At this point, you have the choice of:• Format the unpartitioned/unformatted capacity as a second logical drive• De

Página 197 - Making SLP Settings

VessRAID 1000s Series Product Manual260Predictive Data Migration (PDM)Predictive Data Migration (PDM) is the migration of data from the suspect disk d

Página 198 - Making SNMP Settings

Chapter 8: Technology Background261TransitionThe Transition feature enables you to specify “permanent” spare drives for your VessRAID subsystem. Trans

Página 199 - Managing SNMP Trap Sinks

VessRAID 1000s Series Product Manual262ExampleFollowing is an example to explain the Transition function.In the example above, there is a four-drive R

Página 200 - Managing Netsend Recipients

Chapter 8: Technology Background263There is no spare drive at this moment. Even if physical drive 5 is of adequate capacity, it has not been designate

Página 201 - Netsend Requirements

VessRAID 1000s Series Product Manual122. Insert the two screws that you removed in step 1 through the holes in the left bracket and into the threaded

Página 202 - Flashing through TFTP

VessRAID 1000s Series Product Manual264

Página 203 - Restoring Factory Defaults

265Chapter 9: TroubleshootingThis chapter covers the following topics:• VessRAID is Beeping (below)• LEDs Display Amber or Red (page 266)• CLU Reports

Página 204 - Shutting Down the Subsystem

VessRAID 1000s Series Product Manual266• If email notification is enabled, check for new messages.• Check for yellow !s red Xs in Tree View, see p

Página 205

Chapter 9: Troubleshooting267When the Global Enclosure LED on VessRAID’s front panel shows Amber or Red, check the LEDs on the back of VessRAID. These

Página 206

VessRAID 1000s Series Product Manual268The Power/Activity LED flashes during drive activity.The Disk Status LED displays Green when a drive is present

Página 207

Chapter 9: Troubleshooting269Figure 5. VessRAID Controller LEDs If the Controller Status LED is amber, restart the VessRAID. See “Restarting the Subsy

Página 208

VessRAID 1000s Series Product Manual270If the Controller Status LED continues to display amber after startup, contact Promise Technical Support. See p

Página 209

Chapter 9: Troubleshooting271To display NVRAM events:1. From the Main Menu, highlight Event Viewer and press Enter.2. Highlight NVRAM Events and press

Página 210

VessRAID 1000s Series Product Manual272Physical Drives in the ArrayLogical Drives in the Array[Locate Disk Array]Save Settings [CTRL-A]Restore Setting

Página 211 - Using the LCD Panel

Chapter 9: Troubleshooting273To set up email and popup message notification, see “Setting-up User Event Subscriptions” on page 61.Figure 7. An example

Página 212 - Perusing the Interface

Chapter 2: VessRAID Installation13Mounting VessRAID in a RackThe VessRAID subsystem installs to the rack using the optional mounting rails. You can al

Página 213 - Viewing Events

VessRAID 1000s Series Product Manual274Figure 9. A failed disk drive shown in Management ViewAlso see these troubleshooting topics:• “Event Notificati

Página 214 - Manual IP Settings

Chapter 9: Troubleshooting275LCD Panel Reports a ProblemThe LCD panel can report a certain problems, including a Critical logical drives.Figure 10.The

Página 215 - Automatic IP Settings

VessRAID 1000s Series Product Manual2764. Open the root folder of the USB stick and copy the file subinfo_xxxxxxxxxx.log to the PC desktop or a conven

Página 216

Chapter 9: Troubleshooting277Event Notification ResponseWhen you choose Event Notification, WebPAM PROe sends popup and/or email messages regarding it

Página 217

VessRAID 1000s Series Product Manual278Battery is discharging Battery is undergoing reconditioning.Battery is charging Battery is being recharged.Batt

Página 218

Chapter 9: Troubleshooting279Blowers are functioning normallyNormal.Blowers are NOT installed Reinstall the fan. If the fan does not turn, replace it.

Página 219

VessRAID 1000s Series Product Manual280Drive Interface ControllerDrive-interface controller foundNormal.Drive-interface controller is NOT foundRestart

Página 220

Chapter 9: Troubleshooting281Host-interface controller has encountered an unrecoverable errorRestart the VessRAID. See page 85 (WebPAM PROe) or page 1

Página 221 - Figure 2. Disk Status LED

VessRAID 1000s Series Product Manual282Logical drive initialization has stoppedInitialization stopped because of user intervention, schedule or the lo

Página 222

Chapter 9: Troubleshooting283Media patrol is queued Media patrol has been set manually or by schedule.Media patrol is stopped internallyMedia patrol s

Página 223 - Creating a Disk Array

iiiContentsChapter 1: Introduction to VessRAID . . . . . . . . . . . . . . . . . . . . . . . . . .1About This Manual . . . . . . . . . . . . . . . . .

Página 224

VessRAID 1000s Series Product Manual143. Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your ra

Página 225

VessRAID 1000s Series Product Manual284PDM is stopped internally The destination drive was removed or used for a rebuild.Physical DiskPhysical disk is

Página 226 - Locating a a Disk Array

Chapter 9: Troubleshooting285Physical disk negotiation speed is decreased.Disk drive had to reduce its data rate. If this message appears repeatedly,

Página 227

VessRAID 1000s Series Product Manual286PSU 12V/5V/3.3V power is within the rangeNormal.RAID Level MigrationRAID Level migration is startedResult of se

Página 228

Chapter 9: Troubleshooting287Rebuild is resumed Rebuild has resumed again after a pause.Rebuild is stopped Rebuild stopped because of user interventio

Página 229

VessRAID 1000s Series Product Manual288ResourceResource is NOT availableSystem resources are low. Reduce system load or restart the VessRAID. See page

Página 230 - Locating a a Logical Drive

Chapter 9: Troubleshooting289Synchronization is stoppedSynchronization stopped because of user intervention, schedule or the logical drive was deleted

Página 231

VessRAID 1000s Series Product Manual290Critical & Offline Disk ArraysA fault-tolerant disk array—RAID 1, 1E, 5, 10, and 50—goes critical when a di

Página 232 - Locating a Spare Drive

Chapter 9: Troubleshooting291• The Disk Status LED changes from green to red.Figure 14.VessRAID disk drive carrier LEDs• The audible alarm repeatedly

Página 233

VessRAID 1000s Series Product Manual292To enable Automatic Rebuild, see “Making Background Activity Settings” on page 54 (WebPAM PROe) or page 168 (CL

Página 234

Chapter 9: Troubleshooting293Incomplete ArrayAn incomplete array can result from any of the following conditions:• The NVRAM watermark for the RAID le

Página 235 - Chapter 7: Maintenance

Chapter 2: VessRAID Installation15Installing Disk Drives You can populate the VessRAID with SAS or SATA hard disk drives. For optimal performance, ins

Página 236

VessRAID 1000s Series Product Manual294Physical Drive ProblemsPhysical Drive OfflineCheck the drive for: • PFA Condition – Caused by a bad block or se

Página 237

Chapter 9: Troubleshooting295You can set the VessRAID to migrate disk arrays under Non-Volatile Random Access Memory (NVRAM), a much faster process be

Página 238 - Updating the Firmware

VessRAID 1000s Series Product Manual296Enclosure ProblemsWebPAM PROe displays yellow !s red Xs in Tree View to identify components that need atten

Página 239

Chapter 9: Troubleshooting297EnclosureOverheatOverheating is a potentially serious condition because the excessively high temperatures can lead to dis

Página 240 - Replacing a Power Supply

VessRAID 1000s Series Product Manual298 Power SupplyVessRAID 1800s SeriesVessRAID 1800s Series has two power supplies. The advantage of two power supp

Página 241 - Replacing a RAID Controller

Chapter 9: Troubleshooting299Connection ProblemsWhen you install your Promise product following the instructions in the Quick Start Guide and this Pro

Página 242 - Replacing a Cooling Fan

VessRAID 1000s Series Product Manual300Network ConnectionsEach controller has an Ethernet (RJ45) Management Port connector on the back of the enclosur

Página 243

Chapter 9: Troubleshooting301Browser Does Not Connect to WebPAM PROeIf you successfully setup and connected to WebPAM PROe, then suddenly you can no l

Página 244 - Replacing the Cache Battery

VessRAID 1000s Series Product Manual302Unsaved Data in the Controller CacheThe Dirty Cache LED informs you that there is data in the cache that has no

Página 245

303Chapter 10: Support• Frequently Asked Questions (below)• Contacting Technical Support (page 305)• Limited Warranty (page 309)• Returning the Produc

Página 246 - Replacing the Memory Module

VessRAID 1000s Series Product Manual16Figure 9. VessRAID 1730s and 1830s drive slot numberingInstall all of the drive carriers into the VessRAID enclo

Página 247

VessRAID 1000s Series Product Manual304WebPAM PROe connection was working OK. But later on, it timed out. What do I do now?The network condition can t

Página 248

Chapter 10: Support305How can I be sure everything is working OK on the VessRAID?Locally: The VessRAID enclosure has LEDs on the front to monitor the

Página 249 - Introduction to RAID

VessRAID 1000s Series Product Manual306Technical Support ServicesUnited StatesThe NetherlandsGermanyPromise Online™ Web Site http://www.promise.com/su

Página 250 - RAID 0 – Stripe

Chapter 10: Support307ItalyTaiwan E-mail Support e-Support On-LineFax Support +39 0 6 367 124 00 Attn: Technical SupportPhone Support +39 0 6 367 126

Página 251 - RAID 1 – Mirror

VessRAID 1000s Series Product Manual308China E-mail Support e-Support On-LineFax Support+86 10 8857 8015 Attn: Technical SupportPhone Support +86 10

Página 252 - RAID 1E – Enhanced Mirror

Chapter 10: Support309Limited WarrantyPromise Technology, Inc. (“Promise”) warrants that this product, from the time of the delivery of the product to

Página 253

VessRAID 1000s Series Product Manual310Promise DOES NOT WARRANT that any product is free from errors or that it will interface without problems with y

Página 254

Chapter 10: Support311Returning the Product For RepairIf you suspect a product is not working properly, or if you have any questions about your produc

Página 255 - RAID 10 – Mirror / Stripe

VessRAID 1000s Series Product Manual312You are responsible for the cost of insurance and shipment of the product to Promise. Note that damage incurred

Página 256

313IndexNumerics10GB Truncate 88, 138, 2502 TB Limitation 248, 304Aabout this manual 1adaptive writeback cachedefined 249enable 88, 138alarmcancel 94,

Página 257 - RAID 50 Axles

Chapter 2: VessRAID Installation17Figure 10.Disk drive mounted in a drive carrier This completes disk drive installation.CautionVessRAID supports disk

Página 258

VessRAID 1000s Series Product Manual314command queuing, physical drives 97, 145configuration script, import 79configuration status, physical drive 98c

Página 259 - RAID 60 Axles

Index315disk array, cont.statuscritical 111, 153, 210rebuilding 111, 153, 210synchronizing 111, 153, 210transport ready 111, 153, 210transition 116tra

Página 260 - Choosing a RAID Level

VessRAID 1000s Series Product Manual316forced unlock 58FRU VPD information 92, 140GGB Truncate 88, 138, 250global RAID status LED 290global spare driv

Página 261

Index317LCD panel, cont.deletedisk array 209logical drive 212spare drive 216disk arraycreate, advanced 207create, automatic 206delete 209locate 210vie

Página 262

VessRAID 1000s Series Product Manual318locatecontroller 138disk array 156, 210enclosure 90, 143logical drive 164, 214physical drive 96, 97, 100, 147,

Página 263 - Choosing Sector Size

Index319Oone plug auto service 275online capacity expansion 252reported events 283online helpCLU 133WebPAM PROe 45OPAS 275operational status, disk arr

Página 264 - Cache Policy

VessRAID 1000s Series Product Manual320RAID, contintroduction 233mirror 235mirror + stripe 239stripe 234striping of distributed parity 240striping of

Página 265 - Adaptive Writeback Cache

Index321reported events, cont.online capacity expansion 283PDM 283physical drive 284power supply 285RAID level migration 286rebuild 286, 287Redundancy

Página 266 - Capacity Coercion

VessRAID 1000s Series Product Manual322SNMPservice 76, 183settings 74, 182trap sinks 75, 183Software Services 71Spare Checkreported events 288run 127,

Página 267 - Hot Spare Drive(s)

Index323Transitionautomatic 263defined 261manual 263rate 54, 169reported events 289spare drive 116transportdisk array 117, 154physical drive failure 2

Página 268 - RAID Level Migration

VessRAID 1000s Series Product Manual18Making Data and Management ConnectionsYou can configure your VessRAID for:• Direct Attached Storage (DAS)• DAS p

Página 269

VessRAID 1000s Series Product Manual324WebPAM PROe, cont.Secure Connection 32, 42times out 304Tree View 46write cache policy 112, 120, 151, 158, 208de

Página 270

Chapter 2: VessRAID Installation19Figure 11. Data and management connections This completes data and management connections.CautionMake data connectio

Página 271

VessRAID 1000s Series Product Manual20Setting Up Serial Cable ConnectionsSerial communication enables the Command Line Interface (CLI) and Command Lin

Página 272

Chapter 2: VessRAID Installation21Connecting the PowerPlug-in the power cord on the power supply on the back of the VessRAID enclosure and switch on t

Página 273

VessRAID 1000s Series Product Manual22Controller LEDsWhen boot-up is finished and the VessRAID subsystem is functioning normally:• Battery, and Contro

Página 274

Chapter 2: VessRAID Installation23LCD PanelThe LCD panel activates approximately 35 seconds after you switch on the VessRAID’s power supply.At first,

Página 275 - Media Patrol

VessRAID 1000s Series Product ManualivChapter 2: VessRAID Installation, cont.Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 276 - PDM Triggers

VessRAID 1000s Series Product Manual24

Página 277 - Transition

25Chapter 3: VessRAID SetupThis chapter covers the following topics:• Setting up the Serial Connection (below)• Choosing DHCP or a Static IP Address (

Página 278

VessRAID 1000s Series Product Manual26Choosing DHCP or a Static IP AddressWhen you setup your VessRAID, you have the option of:• Enabling DHCP and let

Página 279 - Manual Transition

Chapter 3: VessRAID Setup27Setting up with the CLI1. Type the following string to set the system date and time, then press Enter. administrator@cli>

Página 280

VessRAID 1000s Series Product Manual28Setting up with the CLU1. At the administrator@cli> prompt, type menu and press Enter.The CLU main menu appea

Página 281 - Chapter 9: Troubleshooting

Chapter 3: VessRAID Setup293. Type the new IP Address.4. Follow the same procedure to specify the Subnet Mask, Gateway IP Address and DNS Server IP Ad

Página 282 - LEDs Display Amber or Red

VessRAID 1000s Series Product Manual30Setting up with the LCDThe LCD Panel displays the current IP address during normal operation. If you did not ins

Página 283 - Disk Drive LEDs

Chapter 3: VessRAID Setup317. Make the needed changes the same as in step 5.After you have set the last (extreme right) digit, press the button.The

Página 284 - Controller LEDs

VessRAID 1000s Series Product Manual32Creating Disk Arrays with WebPAM PROeSetting up disk arrays with WebPAM PROe consists of the following actions:

Página 285

Chapter 3: VessRAID Setup333. When the log-in screen (Figure 2) appears:•Type administrator in the User Name field.•Type password in the Password fiel

Página 286 - CLU Reports a Problem

ContentsvChapter 4: Management with WebPAM PROe,cont.Working with the Storage Network . . . . . . . . . . . . . . . . . . . . . . . . .49Viewing Oth

Página 287 - Checking a Reported Component

VessRAID 1000s Series Product Manual34Choosing a LanguageWebPAM PROe displays in English, German, French, Italian, Spanish, Russian, Japanese, Chinese

Página 288 - WebPAM PROe Reports a Problem

Chapter 3: VessRAID Setup35Figure 5. The Array Configuration menuAutomaticWhen you choose the Automatic option, the following parameters appear on the

Página 289

VessRAID 1000s Series Product Manual36ExpressWhen you choose the Express option, a set of characteristics and options appears on the screen.1. Check t

Página 290

Chapter 3: VessRAID Setup37AdvancedStep 1 – Disk Array Creation1. Enter a name for the disk array in the field provided. 2. Check the boxes to enable

Página 291 - Viewing a Report from OPAS

VessRAID 1000s Series Product Manual385. Specify a Stripe size from the dropdown menu.64, 128, 256, 512 KB, and 1 MB are available. 64 KB is the defau

Página 292

Chapter 3: VessRAID Setup39Using WebPAM PROe over the InternetThe above instructions cover connections between VessRAID and your company network. It i

Página 293 - Event Notification Response

VessRAID 1000s Series Product Manual40

Página 294

41Chapter 4: Management with WebPAM PROeThis chapter covers the following topics:• Logging into WebPAM PROe (page 42)• Perusing the Interface (page 44

Página 295

VessRAID 1000s Series Product Manual42Logging into WebPAM PROe 1. Launch your Browser.2. In the Browser address field, type the IP address of the Vess

Página 296

Chapter 4: Management with WebPAM PROe43Figure 1. WebPAM PROe log-in screenAfter sign-in, the WebPAM PROe opening screen appears. If there are any unc

Página 297

VessRAID 1000s Series Product ManualviChapter 4: Management with WebPAM PROe,cont.Managing the Network Connection . . . . . . . . . . . . . . . . . .

Página 298

VessRAID 1000s Series Product Manual44Figure 2. Clicking “Language” on the WebPAM PROe bannerPerusing the InterfaceWebPAM PROe is browser-based RAID m

Página 299

Chapter 4: Management with WebPAM PROe45There are four major parts to the graphic user interface:• Header (see below)• Tree (see page 46)• Management

Página 300

VessRAID 1000s Series Product Manual46Using Tree ViewTree View enables you to navigate around all components of the Subsystem, including SAS managemen

Página 301

Chapter 4: Management with WebPAM PROe47Using Management ViewManagement View provides the actual user interface with the VessRAID, including creation,

Página 302

VessRAID 1000s Series Product Manual48Click the link a second time to change to flip the triangle and reverse the sort sequence.Logging out of WebPAM

Página 303

Chapter 4: Management with WebPAM PROe49Working with the Storage NetworkWhen you log into WebPAM PROe, you access a specific VessRAID subsystem. See “

Página 304

VessRAID 1000s Series Product Manual50Working with SubsystemsA VessRAID subsystem is identified by its Management Port IP address. Subsystem functions

Página 305

Chapter 4: Management with WebPAM PROe51Setting an Alias for the SubsystemAn alias is optional. To set an alias for this subsystem:1. In Tree View, cl

Página 306 - When a Physical Drive Fails

VessRAID 1000s Series Product Manual52• Time – Time and date of the occurrence • Description – A brief description of the event 3. Click the link at t

Página 307 - Without a Hot Spare Drive

Chapter 4: Management with WebPAM PROe53• Item Number – A consecutive decimal number assigned to a specific event • Device – Battery, controller, logi

Página 308 - Rebuild Operation

ContentsviiChapter 4: Management with WebPAM PROe,cont.Managing Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90Vie

Página 309 - Incomplete Array

VessRAID 1000s Series Product Manual54Viewing Current Background ActivitiesTo view the current background activities:1. In Tree View, click the Subsys

Página 310 - Physical Drive Problems

Chapter 4: Management with WebPAM PROe55• Reassigned Block Threshold – 1 to 512 blocks• Error Block Threshold – 1 to 1024 blocks5. Check to enable or

Página 311

VessRAID 1000s Series Product Manual56Running PDMPredictive Data Migration (PDM) migrates data from the suspect physical drive to a spare disk drive,

Página 312 - Enclosure Problems

Chapter 4: Management with WebPAM PROe575. Select a Recurrence Pattern. • Daily – Enter the number of days between events. • Weekly – Enter the number

Página 313

VessRAID 1000s Series Product Manual58Viewing Lock StatusThe lock prevents other sessions (including by the same user) from making a configuration cha

Página 314

Chapter 4: Management with WebPAM PROe594. Enter a time interval between 1 and 1440 minutes (one day) that you want the lock to stay active.The renew

Página 315 - Connection Problems

VessRAID 1000s Series Product Manual60Managing UsersUser Management includes all functions dealing with user accounts. Functions include:• Viewing Use

Página 316 - Network Connections

Chapter 4: Management with WebPAM PROe61• Enter or change the email address. • From the Privilege dropdown menu, choose a new level.See “List of User

Página 317

VessRAID 1000s Series Product Manual62• Fatal – Non-Recoverable error or failure has occurred • None – Deactivates this event for notification purpose

Página 318

Chapter 4: Management with WebPAM PROe638. Enter the new password in the Retype Password field. 9. Click the Submit button. Creating a UserTo create a

Página 319 - Chapter 10: Support

VessRAID 1000s Series Product ManualviiiChapter 4: Management with WebPAM PROe,cont.Managing Disk Arrays, cont.Running Media Patrol on a Disk Array .

Página 320

VessRAID 1000s Series Product Manual64Deleting a UserThere will always be at least one Super User account. You cannot delete the user account you used

Página 321 - Contacting Technical Support

Chapter 4: Management with WebPAM PROe65Managing the Network ConnectionThe network connection deals with the VessRAID’s Management Port.• Making Manag

Página 322 - The Netherlands

VessRAID 1000s Series Product Manual66Managing SAS ConnectionsSAS connections deal with the VessRAID’s two host data ports.• Viewing SAS Port Informat

Página 323

Chapter 4: Management with WebPAM PROe67The range is 1 to 8. 1 is the default. Signal strength correlates to cable length in meters. Example: If you h

Página 324 - Attn: Technical Support

VessRAID 1000s Series Product Manual68Managing Storage ServicesStorage services deal with initiators and LUN mapping. LUN masking is the process of ap

Página 325 - Limited Warranty

Chapter 4: Management with WebPAM PROe693. Click the Storage Services icon. 4. Click the Initiators tab in Management View. 5. From the Initiators t

Página 326 - Your Responsibilities

VessRAID 1000s Series Product Manual70You must enter different LUN numbers for each logical drive.7. Click the Submit button. Editing a LUN MapTo edit

Página 327

Chapter 4: Management with WebPAM PROe71Managing Software ServicesSoftware Services include the following functions:• Making Email Settings (page 71)•

Página 328

VessRAID 1000s Series Product Manual72Changing the Startup Setting1. Under Startup Type: • Click the Automatic option to start the service automatical

Página 329

Chapter 4: Management with WebPAM PROe73Making Web Server SettingsThe Web Server service connects your browser to the WebPAM PROe GUI on the VessRAID

Página 330

ContentsixChapter 5: Management with the CLU, cont.Managing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137Viewing

Página 331

VessRAID 1000s Series Product Manual74Making Telnet SettingsVessRAID’s Telnet service enables you to access VessRAID’s Command Line Interface (CLI) th

Página 332

Chapter 4: Management with WebPAM PROe75To change the SNMP settings:1. Click the Subsystem icon in Tree View. 2. Click the Administrative Tools ic

Página 333

VessRAID 1000s Series Product Manual764. Click OK in the confirmation box.Changing the Startup Setting1. Under Startup Type: • Click the Automatic opt

Página 334

Chapter 4: Management with WebPAM PROe775. Click OK in the confirmation box.Deleting Netsend RecipientsTo delete a Netsend recipient:1. Highlight the

Página 335

VessRAID 1000s Series Product Manual78Exporting the User DatabaseYou can export the User Database file to share user information and settings among mu

Página 336

Chapter 4: Management with WebPAM PROe795. Under the Type dropdown list, choose User Database. 6. Enter the name of the file to be imported.Or, click

Página 337

VessRAID 1000s Series Product Manual80The new configuration is applied to this VessRAID subsystem. Updating the FirmwareSee “Chapter 7: Maintenance” o

Página 338

Chapter 4: Management with WebPAM PROe81Restoring Factory DefaultsVessRAID includes a function to restore the default settings to its Firmware and Sof

Página 339

VessRAID 1000s Series Product Manual82Shutting Down the SubsystemYou can only do part of this function in WebPAM PROe. Additional action is required,

Página 340

Chapter 4: Management with WebPAM PROe83Monitoring the ShutdownTo monitor a shutdown, you must use the Command Line Interface (CLI) though a serial co