Offline Array Recovery Procedures—SuperTrak SX6000 and UltraTrak, Version 5a
19 of 34
Case 3: Array goes offline due to a general power
problem.
1. Turn off the power.
2. Determine the cause of the power problem and correct it.
3. Reboot the system. Array status should be FUNCTIONAL.
Important
If the array goes OFFLINE rather than FUNCTIONAL, follow these steps:
a. Shut down the system.
b. Boot (turn on) the SuperTrak PC or the UltraTrak.
c. Delete the existing array and create a new one.
Warning: This procedure may result in data loss. Follow instructions
carefully.
Refer to the sections SuperTrak BIOS Recovery Procedure on page 23,
or UltraTrak Recovery Procedure on page 29, for step-by-step
instructions.
d. Reboot the system. Array status will be FUNCTIONAL.