Promise Technology Network Device EX8650 Manual do Utilizador Página 278

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 277
SuperTrak EX Series User Manual
264
Figure 3. Physical Drive Management screen
In the example above, there is no physical drive for ID 3. Assuming you
installed a physical drive onto Channel 3 of the SuperTrak controller, this is
the failed physical drive.
3. Shut down the Host PC, open the case, check the power and data
connections to each physical drive, correct any shortcomings, restart the
Host PC and check in SuperBuild again.
Finding the Failed Drive in WebPAM PRO
To locate a failed or missing physical drive:
1. Open WebPAM PRO.
See “Logging into WebPAM PRO” on
page 107 for more information.
2. Click the Subsystem icon in Tree View.
3. Click the Enclosures icon.
4. Click the Enclosure icon.
5. Click the Physical Drives icon.
6. Examine the list of physical drives.
If a drive was present but is now
missing, that is the failed drive. Check
the power and data connections. If
those are OK, you must replace the
drive.
If a drive is marked as PFA or Stale,
that is the problem drive and you might
be able to salvage the drive.
If a drive is marked as Offline or Dead,
that is the problem drive and you must replace it.
ID 3 is missing
Vista de página 277
1 2 ... 273 274 275 276 277 278 279 280 281 282 283 ... 317 318

Comentários a estes Manuais

Sem comentários