Chapter 9: Technology Background
357
RAID 30
A RAID 30 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 3
RAID 5
32 physical drives maximum.
RAID 30 must have less than 32 physical drives.
RAID 6 32 physical drives maximum.
RAID 50 must have less than 32 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Even number of physical drives.
RAID 30 Add physical drives. 32 per axle maximum.
RAID 50 6 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.